300 LED Series

Series key features:

  • 5 LEDs
  • Shadowless light
  • Triple-axis head movement
  • Light intensity control
  • Auto ON/OFF with preset chair positions*
  • Touchless sensor switch
  • Easy-clean, smooth surfaces
  • Zero-drift balance-arm
  • Mounting options
  • Retrospective-fitting option

* Applies to Chair- and Unit-mounted versions only

Explore in detail >


2019 Offers +

FREE upgrade to 320 LED light
with every Voyager III treatment centre.

Source better value >

Series key technical features:

  • White natural beam, 5000 Kelvin (5 LEDs)
  • Stepless control of light intensity between 3,100 and 28,000 Lux
  • Composite Curing Safe Mode (at 4,300 Lux)
  • 85x155mm light pattern at 650mm focal distance

Pole lengths include 100cm (standard) and 150cm (optional).

Maximum ceiling height 305cm in respect of a 100cm pole.


Model Options:

  • 301U LED post-mounted
  • 302C LED ceiling-mounted
  • 320LR LED unit-mounted for Voyager III

MODEL OPTIONS

302 LED Chair-mounted

302 LED ceiling-mounted (suitable for a maximum ceiling height 305cm)

Belmont equipment advice after lockdown

You might be wondering what you should do with your treatment centre before re-opening your practice or is there any protocol that you should be following. We are sharing with you 8 Simple Steps on how to protect your dental equipment when leaving unused for long periods. Please read carefully prior to taking any action.

  1. Follow your normal waterline maintenance protocol in accordance with CQC guidelines until complete shutdown.
  2. If complete shutdown for an unspecified period of time is imminent take off the clean water bottle and tip any residue water away and put the bottle back on empty. After removing the couplings and handpieces from the delivery system hold the hoses over a bucket and press the flush button or run the automatic flush if your unit has one. It’s important remembering while flushing to press the syringe buttons in order to release any trapped water and continue to run the flush until the handpiece hoses run dry.
  3. Do not forget to clean your suction hoses and spittoon with your recommended suction cleaner. Then run water through the hoses to make sure any residue left in the hoses is diluted down.
  4. Make sure the suction pump is switched on before cleaning the hoses.
  5. When the system is completely dry and the suction hoses cleaned switch the main chair switch off and any chair isolator in the room “turn off”.
  6. If all the treatment centres in the practice are to be shutdown for a period of time make sure the staff turn off the compressor and the suction pump.
  7. If you are concerned about shutting down your equipment call your equipment dealer to help you run through this process safely. They will always be happy to help and advise at this difficult time.
  8. When the time comes to return the dental treatment centre back to full use, please be aware that you will need to test your waterlines as per your normal CQC protocol. This action is essential part of the process as you want to check that you don’t have any biofilm build-up during the period of stagnation.

We wish you and your families a safe transit through this difficult time. We are at our disposal to assist you with any further details: dental@takara.co.uk or service@takara.co.uk.

 